41 water meter installation diagram
(7) The water meter should be installed by a qualified, experienced professional. Upon installation, each water meter must be inspected by District staff. If you have any questions regarding installation of water meters or would lik e to schedule an inspection, please do not hesitate to call (831) 658-5642. revised 04/13/2000 GETTING TO KNOW YOUR METER ASSEMBLY Diagram of Typical Meter Installation. Meter Assembly Component 1. Isolation Valve (attached to waterline from street) 2. Water Meter Frost Plate (sacrificial black steel, under meter, will break if frozen) 3. Water Meter Base 4. Water Meter Register Head 5. Dual Check Backflow Preventer (DuC) 6.
W-31 Typical 1 ½ "- 2" Water Meter Box Installation W-32 Typical 4" Water Meter Vault W-33 Typical 6" thru 10" Water Meter Vault W-34 Fire, Domestic & Irrigation Options Schematic W-35 Irrigation Tap on New and Existing Services W-35T Termination of Irrigation Meter W-36 Reduced Pressure Backflow Preventer ...
Water meter installation diagram
Flow Meter Installation This next photograph shows a very poor orifice plate installation, where the straight-run pipe requirements were completely ignored: Not only is the orifice plate placed much too close to an elbow, the elbow happens to be on the upstream side of the orifice plate, where disturbances have the greatest effect! Installation of a venturi meter. Proper installation of venturi meter is the key for ideal operation. So, the installation of venturi meters must be performed following manufacturer guidelines. Normally, the following guidelines to be followed while installing a venturi meter in a piping or pipeline system: for after hours emergencies please dial 914-524-8879. for billing, scheduling repairs, turn on/turn off dial 914-788-3400. for markouts call dig safely ny at 811 or 1-800-962-7962
Water meter installation diagram. May 04, 2021 · R.T.U. Installation Wiring Diagram: E-7: Electrical Riser Diagram and Emergency Generator Bldg. Floor Plan . Appendix F - Turbine Meter Guidelines. Sheet No. Title. PDF. DWG. Drawing No. WM-1: Water Main Turbine Meter Design Guide Plan, Sections and Details . W-00000-A . Appendix G - Sewer Meter Station Guidelines. Sewer Meter Station. Sheet No ... 7.3. supply types and arrangements 40 8. storage cisterns,water pumps and other miscellaneous 44 8.1. storage cisterns (or water tanks) 44 8.2. water pumps 47 8.3. valves and taps 47 8.4. earthing 48 8.5. separate metering in existing premises 48 8.6. authorizing private developers/authorized persons to undertake water supply connection works 49 9. 1.3 WATER METER The water meter shall meet or exceed the following requirements: Volumetric rotary piston principle of measurement 15mm, 20mm or 25mm Class C, 114mm plastic rotary piston meter with liquid sealed mechanical transmission/flow with direct reading counter, high reliability, high precision Conform to NRCS 1529-1 Drawings for Cathodic Protection for water mains and modifications to installation requirements for domestic water meters to better accommodate AMI meters. This edition of “Standard Drawings for Water and Wastewater Construction” is written by Engineering Services, Dallas Water Utilities.
Water Meter The water meter provides essential data to the KalGUARD controller to ensure intelligent activation of the KalGUARD anode unit. It is NOT intended for direct paralleling with a BMS for volumetric water coupling (see later – “Installation of Electrics/ Electronics"). Following the completion of the "Meter" - a device for measuring the electric power and energy supplied to a customer. 22. "Meter Enclosure" - a wood or metal cabinet, or metal socket, installed indoors or outdoors, in which the Company's metering equipment is located. 23. "Meter Sockets" - a meter socket is the base portion of a socket type meter. There separate cold water riser tube from faucet shank. Gently bend riser tube so that the Feed Water Adapter (Fig 5) fits onto the faucet shank. If your riser tube has no built-in washer, then fit the cone-shaped washer provided onto the riser tube. Connect the riser tube, the feed water adapter, and faucet shank together and tighten. See Appendix 1 - Diagram 2 (page 8) which shows an illustration of a typical single meter installation of in-line meter internal (not on manifold). Diagram 3 (page 9) shows, a meter carrier for a single and/or multiple internal meter installation (which can also be used on a multiple manifold).
) But the depth of a river water pick-up for a 2-line or 1-line jet pump can be important for other reasons: 1. the water pick-up point for any water pump system needs to be high enough off the bottom to avoid picking up sand or silt and mud - those will foul the whole water system. In a well that may be 4-10 ft. The below diagram shows how a 20mm water meter and service line should be positioned in relation to the front boundary line and the finished ground level. Please note the clearances required. The new location will need to have these minimum clearances when relocating your water meter. Installation Notice. Installed at the lowest point and vertical upward direction Install exhaust valve at the downstreat of flow meter. Don’t install at the highest point and vertical downward diection when drop is more than 5m. Installed at the lowest point when used in open drain pipe Need 10D of upstreat and 5D of downstreat. Sep 30, 2004 · LANL Standard Drawings and Details either (1) depict required format/content or (2) are templates that are completed by a Design Agency (LANL or external AE) for a design drawing package, in a manner similar to specifications.
Complete this form for all water and sewer connections and disconnections, water main drilling and pre-laid services drilling (minor works), water meter installation, recycled water connections and recycled water meter installation applications. You can select multiple application types when completing this …
In modern plumbing, a drain-waste-vent (or DWV) is part of a system that allows air to enter a plumbing system to maintain proper air pressure to enable the removal of sewage and greywater from a dwelling. Waste is produced at fixtures such as toilets, sinks, and showers. As the water runs down, proper venting is required to avoid a vacuum from being created.
for after hours emergencies please dial 914-524-8879. for billing, scheduling repairs, turn on/turn off dial 914-788-3400. for markouts call dig safely ny at 811 or 1-800-962-7962
Harga Meteran Air Counter Kelas B Iso 4064 Perumahan Buy Perumahan Meter Air Harga Counter Meter Air Iso 4064 Kelas B Meter Air Product On Alibaba Com
Installation of a venturi meter. Proper installation of venturi meter is the key for ideal operation. So, the installation of venturi meters must be performed following manufacturer guidelines. Normally, the following guidelines to be followed while installing a venturi meter in a piping or pipeline system:
Flow Meter Installation This next photograph shows a very poor orifice plate installation, where the straight-run pipe requirements were completely ignored: Not only is the orifice plate placed much too close to an elbow, the elbow happens to be on the upstream side of the orifice plate, where disturbances have the greatest effect!
Diagram Perakitan Suku Cadang Meteran Air Buy Meter Air Aksesoris Plastik Meter Air Fittings Pasokan Air Fitting Product On Alibaba Com
0 Response to "41 water meter installation diagram"
Post a Comment